This page is for discussion about a planned cycle of improvements to Freeside.


A Punch List of tasks to be accomplished is [["Improve Electrics PUNCH LIST"| here]].
<big>Projects</big>
* Electrical
:* Next Step: 
::* [ ] Clarify steps required to get a project approved for work by others.


<pre>
As an example, what steps are required by Freeside in order to have work done that will make the kiln usable by members or guests?
Written in org-mode
* Projects
** Electrical
</pre>




[[Media:Workshop_Plan_Proposal.pdf|Floorplan submitted by Slade]]
Punch List


 
:::* In
Some deliverables absolutely require a licensed electrician.  Given that, we aim to identify all deliverables that do require an electrician, as well as other deliverables that can better be addressed by an electrician, assuming that we engage one for a deliverable requiring a permit.
::::* run code electrical to light in kitchen
 
::::* Run electrical to Form1 room
Installing power for the kiln (many Freesiders await the ability to use our fine kiln) requires 240V power, and hence a permit, and hence a licensed electrician. A number of other desired improvements would benefit from the installation of 240V power in convenient places.
::::* Run electrical to kiln
Installing power more conveniently located in the non-metal area of the workshop would require 120V power, and woul require a permit, and hence an electrician.
:::::* Per Scott, " Pretty sure it's split phase 240. Pretty sure it just needs a 50A split phase outlet to run on 208V at a lower temperature/ramp."
 
::::* hole in outlet above projector
Some deliverables might not require a permit or licensed electrician, such as connecting wired outlets to existing power in junction boxes.
::::* inspect for exposed outlets
 
::::* install lights in hallway
We need to finalize our agenda for use when conferring with an electrician. Jud has contacted two.  One has responded. However, these quotes will not address the agenda we will soon create, so these quotes will be used as references.
:::* Considering
<pre>
::::* run electrical to outlets on wall between work tables and admin closet
 
::::* Remove dropped quads from above work tables in front
*** In Scope
::::* replace removed dropped quads above work tables with outlets at wall for each table
 
::::* 120v cables to quads in workshop
**** Need an electrician
::::* 240v to front left corner of auto bay
***** 220V
::::* 240v to large air compressor
****** Power requirements
::::* 240v to welding table
- 50A to welding table (drop from ceiling, plug to match current MIG welder)
- 50A to kiln (plug to match kiln) Can run along the back side of the wall above the door openings, or ceiling
- At least 30A to air compressor (plug to match compressor) Can run along the back side of the wall above the door openings, or ceiling
 
***** 120V
- lights outside in the back need to be wired in. The two outer ones are new installs, the center one is old and may not work.  
- add a switched circuit for lighting over the machine shop and auto bay. Switch should be located near the west door, switched junction boxes on the ceiling near the back of the bays (this will allow someone coming in from the back of the space to turn lights on once we have access control) Freeside can install appropriate lighting fixtures here once the wiring is there to support it.  
- add more 120 to the East wall and South wall of the shop (where the miter saw is) from one of the main junction boxes for additional power tool usage. 1 4 gang plug centrally located on the South wall, one 2 gang plug on the East wall every X (10?) feet all the way to the back of the space*, including the auto bay. From this Freeside will take care of running the floor channels as needed based upon the shop layout. *If it is easier to run 120 to the East wall in the auto bay from the West wall while running the for the compressor and kiln, that works too.
 
 
*** Out of scope/Freeside can handle
 
**** Might not need an electrician
****** light in kitchen
Do not want to use outlet just above light because that is not switched
****** Connect power to Form1 room
Existing work
****** Connect power to Art wall
Existing work
****** lights in hallway
Existing work
 
**** Do not need an electrician
Inspect every wall and ceiling for outlet boxes or junction boxes that need faces or prot holes covered
 
*** Considering to Move Into Scope
**** [Empty]
</pre>


:::* Electricians Contacted:
:::* Electricians Contacted:
::::* Greg Pica of Socket Doctors
::::* Greg Pica of Socket Doctors


:::::* [[Media:socket_doctor.jpg|business card]]
[[Media:socket_doctor.jpg|business card]]


:::::* No document (quote or estimate) received yet. (27 September)
:::::* No document (quote or estimate) received yet. (27 September)
Line 68: Line 38:
:::::* Phone: +1-470-301-7696
:::::* Phone: +1-470-301-7696


:::::* [[Media:Screenshot_20160928-151459.png|Estimate Document]]
[[Media:Screenshot_20160928-151459.png|Estimate Document]]
 
* [[Media:20160929_135417.jpg|Sub-panel B]]
 
* [[Media:20160929_135426.jpg|Contents - Sub-panel B]]
 
[[One-if-by-land-three-if-by-air|Alternatives for last mile]]

Revision as of 13:34, 29 September 2016

Projects

  • Electrical
  • Next Step:
  • [ ] Clarify steps required to get a project approved for work by others.

As an example, what steps are required by Freeside in order to have work done that will make the kiln usable by members or guests?


Punch List

  • In
  • run code electrical to light in kitchen
  • Run electrical to Form1 room
  • Run electrical to kiln
  • Per Scott, " Pretty sure it's split phase 240. Pretty sure it just needs a 50A split phase outlet to run on 208V at a lower temperature/ramp."
  • hole in outlet above projector
  • inspect for exposed outlets
  • install lights in hallway
  • Considering
  • run electrical to outlets on wall between work tables and admin closet
  • Remove dropped quads from above work tables in front
  • replace removed dropped quads above work tables with outlets at wall for each table
  • 120v cables to quads in workshop
  • 240v to front left corner of auto bay
  • 240v to large air compressor
  • 240v to welding table
  • Electricians Contacted:
  • Greg Pica of Socket Doctors

business card

  • No document (quote or estimate) received yet. (27 September)
  • Twon of AG Electrical LLC
  • Phone: +1-470-301-7696

Estimate Document